Alerts
If a tracker transmits an 'alert' message, you will now see an"alert='true'"parameter, as well as an"alertType="BUTTON""parameter. "The alertType parameter could have
any of these values:
"
The user has pressed the red alert button
The bluetooth connection has been lost
The countdown timer has timed-out
The dead-man timer wasn't reset in time
The tracker "has moved too far from it's geofence centre
The user has cancelled any previous alerts (this is a menu option on the tracker).
External power (5V) has been disconnected
Temperature outside preset range.
"
Important note regarding ‘Iridium’ position reports:
We can report transmissions to you that"may not"have a valid GPS fix. "Typically this happens if it has a poor view of the sky, but there are other occasions when it will
transmit a message without a GPS position. "In this case, we do get an approximate position from the Iridium network. "This ranges in accuracy - often it can be within a
few km, or it may be 200km out.
"
There is a"source="GPS""or"source="IRIDIUM""parameter in every <position/> element. "If it's an Iridium position, you"won't get"sog,"cog"or"alt"parameters. "You"will get"a
cep="123""parameter, which indicates the accuracy (in km) of the reported position.
"
It's necessary for us to tell you about Iridium positions, because it is possible that the tracker can report an alert with no GPS fix.